+Carton
+ISB
+Peacock
+Sunever
+Teclock
+Well Air
Durability is pursued by protecting mechanical parts like gears with shock absorbing mechanism (Teclock unique shock proof mechanism).
Jeweled bearing is applied for improving durability.
Stable repeatability accuracy is realized with lever enlargement mechanism built–in.
Tolerance hand is provided as standard accessory for all models for positive tolerance setting.
Popular type |
Model | TM-1201 |
Graduation | 0.001 (mm) |
Range | 1(3) (mm) |
Repeatability | 0.5 (µm) |
Indication Error |
Adjacent 2.5 (µm) 1/2 Revolution ±3 (µm) 1 Revolution ±4 (µm) 2 Revolution ±4 (µm) Total Range ±5 (µm) |
Hysteresis | 3 (µm) |
Measuring force |
1.5 or less (N) |
Weight | 170 (g) |
Oil-proof type |
Model | TM-1201PW |
Graduation | 0.001 (mm) |
Range | 1(3) (mm) |
Repeatability | 0.5 (µm) |
Indication Error |
Adjacent 2.5 (µm) 1/2 Revolution ±3 (µm) 1 Revolution ±4 (µm) 2 Revolution ±4 (µm) Total Range ±5 (µm) |
Hysteresis | 3 (µm) |
Measuring force |
1.5 or less (N) |
Weight | 180 (g) |
Wide graduation width type |
Model | TM-1251 |
Graduation | 0.001 (mm) |
Range | 1(3) (mm) |
Repeatability | 0.8 (µm) |
Indication Error |
Adjacent 2.5 (µm) 1/2 Revolution ±3 (µm) 1 Revolution ±4 (µm) 2 Revolution ±4 (µm) Total Range ±5 (µm) |
Hysteresis | 3 (µm) |
Measuring force |
1.5 or less (N) |
Weight | 170 (g) |
Type suitable to Boregauge |
Model | TM-1202 |
Graduation | 0.001 (mm) |
Range | 2(2) (mm) |
Repeatability | 0.5 (µm) |
Indication Error |
Adjacent 4 (µm) 1/2 Revolution ±5 (µm) 1 Revolution ±6 (µm) 2 Revolution ±6 (µm) Total Range ±7 (µm) |
Hysteresis | 3 (µm) |
Measuring force |
1.5 or less (N) |
Weight | 170 (g) |
5mm stroke type |
Model | TM-1205 |
Graduation | 0.001 (mm) |
Range | 5(-) (mm) |
Repeatability | 1 (µm) |
Indication Error |
Adjacent 5 (µm) 1/2 Revolution ±9 (µm) 1 Revolution ±7 (µm) 2 Revolution ±8 (µm) Total Range ±10 (µm) |
Hysteresis | 4 (µm) |
Measuring force |
1.5 or less (N) |
Weight | 170 (g) |